Related Experiment Video
Updated: Nov 30, 2025

Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Does Q-MIX pretreatment improve the dentin bond durability of a two-step self-etch adhesive?
Safa Tuncer1, Neslihan Tekçe2, Mustafa Demirci1
1Faculty of Dentistry, Department of Restorative Dentistry, Istanbul University, Istanbul, Turkey.
Abstract:
This study aims to analyze and assess the effects of three particular dentin pretreatment solutions on the bond durability of a two-step self-etch adhesive (Optibond XTR) applied to dentin after ageing for 2 years. Thirty-five third molars which were extracted (n = 5 for μTBS, n = 2 for nanoleakage) were divided into five groups: Group 1:Control (no pretreatment), Group 2:17% EDTA, Group 3:2% CHX, Group 4:17% EDTA plus 2% CHX, Group 5: Q-Mix. After the pretreatments of dentin, the dentin adhesive was applied as per the guidelines provided by the manufacturer. Half of the specimens were subjected to μTBS tests for 24 hr, while the remaining half were subjected to the tests after being kept for 2 years in water storage. Also, nanoleakage was evaluated with FE-SEM by examining silver nitrate deposits. The data obtained were evaluated using a two-way analysis of variance and Tukey Post Hoc test. The dentin pretreatments did not affect the 24 hr and 2 years μTBS values for OptiBond XTR. At 24 hr, the EDTA + CHX group (50.3 ± 4.9) showed that the highest μTBS value was obtained. Water ageing significantly reduced the μTBS results and after 2 years the highest μTBS value was obtained from the Q-Mix group (37.7 ± 5.2). Different dentin pretreatments do not alter the 24-hr μTBS and were not able to preserve the bond strength after 2 years of ageing. Q-Mix was able to slow down the regression in the strength of the dentin bond as well as nanoleakage over time.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Bonding and Strength of Aggregate
Testing Water Quality