Related Experiment Video
Updated: Nov 30, 2025

Three-Dimensional Preoperative Virtual Planning in Derotational Proximal Femoral Osteotomy
Published on: February 17, 2023
How do lateral hinge and distraction affect three-dimensional rotation in open wedge high tibial osteotomy?
Shih-Sheng Chang1, Shang-Chih Lin2, Yi-Sheng Chan3
1Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan; Department of Orthopedic Surgery Division of Sports Medicine and Musculoskeletal Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan.
Background:
Open-wedge high tibial osteotomy (OWHTO) has extensively been used for the correction of medial knee osteoarthritis. The proximal tibia is osteotomized and distracted to enable the rotation of tibial fragments around the lateral hinge. Both, wedge inclination on the medial side and saw progression near the lateral cortex determine the hinge orientation. This study focused on the interaction between hinge orientation and distraction sites on the coronal, sagittal, and horizontal planes of the distracted plateau.
Methods:
Three parameters of wedge inclination, saw progression, and distraction site (i.e., posterior, middle, and anterior) were systematically varied. Using a three-dimensional (3D)-printing technique, the osteotomized tibiae were manufactured as the specimens for the in vitro experiments. In total, 27 variations (3 × 3 × 3) were tested. After distraction, the specimens were scanned by computed tomography and spatially registered with the original tibia to compare the 3D angles of the distracted plateaus.
Results:
Coronal rotation is the main purpose of OWHTO; therefore, all the values of the coronal angles were positive and significantly higher than the other two. The sagittal and horizontal angles had relatively similar values. Distraction in the middle site seems to have the least impact on sagittal rotation. Large angles of hinge orientation show the superior ability in adjusting the sagittal rotation than small angles. However, the larger the horizontal angles the greater the wedge inclination.
Conclusions:
The wedge inclination, saw progression, and distraction site constitute a complex mechanism that affects 3D rotations of the distracted plateau. The coronal angles are sensitive to hinge orientation and distraction site. The intraoperative planning of manipulating hinge orientation is an effective method to adjust sagittal rotation. A large angle of wedge inclination is an indicator of horizontal rotation, and it should be carefully mitigated to reduce the risk of cracking in the lateral hinge.