Related Experiment Video
Updated: Nov 30, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Very low blood flow carbon dioxide removal system is not effective in a chronic obstructive pulmonary disease
Raphaël Giraud1,2,3, Carlo Banfi2,3,4,5, Benjamin Assouline1,3
1Intensive Care Unit, Geneva University Hospitals, Geneva, Switzerland.
Abstract:
Extracorporeal carbon dioxide removal (ECCO2 R) is a low blood flow veno-venous extracorporeal membrane oxygenation technique that provides artificial blood CO2 removal. Recently, a new ECCO2 R system (PrismaLung), providing very low blood flow has been commercialized. The aim of this study is to report its use in severe chronic obstructive pulmonary disease (COPD) patients needing an ECCO2 R therapy. Six severe COPD patients with acute exacerbation leading to refractory hypercapnic respiratory acidosis were treated with ECCO2 R therapy. Two different systems were used: a PrismaLung system and a conventional ECCO2 R device. The maximum blood flow provided by PrismaLung was significantly lower than that with the conventional ECCO2 R system. In three patients initially treated with PrismaLung, there were no improvements in pH, PaCO2 , or RR. Thus, the therapy was switched to a conventional ECCO2 R system in these three patients, and three others were treated from the outset by the conventional ECCO2 R system, providing significant improvement in pH, PaCO2 , and RR. The present retrospective study describes the first use of PrismaLung in severe COPD patients with acute exacerbation. When compared with a higher blood flow ECCO2 R system, our results show that this novel, very low-flow device is not able to remove sufficient CO2 , normalize pH or decrease respiratory rate.
More Related Videos
04:03Author Spotlight: Evaluating the Therapeutic Efficacy of Moving Cupping Along Meridians for Acute Exacerbation of COPD
Published on: September 27, 2024
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
COPD: Management Using Bronchodilators and Corticosteroids
Acute Respiratory Failure-III
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...