Feasibility Study of a Hybrid Closed-Loop System with Automated Insulin Correction Boluses
Revital Nimri1, Benyamin Grosman2, Anirban Roy2
1The Jesse Z and Sara Lea Shafer Institute for Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel, Petah Tikva, Israel.
Abstract:
The Medtronic MiniMed™ 670G system adjusts basal insulin delivery in response to continuous glucose monitoring levels and is already in use in clinical practice. We tested the home-based feasibility of the new MiniMed advanced hybrid closed-loop (AHCL) system, which includes several algorithm enhancements and an optional autocorrection bolus mode. Twelve adolescents and young adults (eight females) with type 1 diabetes [median (interquartile range)] aged 16.6 (15.9, 18.2) years and diabetes duration of 7.1 (4.7, 8.8) years] participated in this single-arm study. The first stage was a 6-day open-loop run-in period, with the predictive low-glucose suspend feature on. This was followed by 6 days/5 nights in a supervised hotel setting, using the AHCL system, including closed-loop challenges (missed meal bolus, late meal bolus, and physical activity); and finally, 3 weeks with unrestricted home use. Glycemic parameters were compared between the open-loop and closed-loop periods. Participants spent 93.3% (4.7) of the time in SmartGuard™ Auto Mode. Hemoglobin A1C levels decreased from median (interquartile range) 7.1% (6.7, 7.9) at baseline to 6.8% (6.6, 7.4) at study end, after 4 weeks (P = 0.0027). Time in range (TIR) (70-180 mg/dL) was 68.4% (10.6) and time below 70 mg/dL was 4% (3.5) during open-loop; and 74% (6.1) and 2.6% (1.9), respectively, during the closed-loop at home phase (P = 0.06, P = 0.27). TIR increased during the nighttime, from 64.6% (17.4) to 80.7% (7.8), P = 0.007, without change in time below 70 mg/dL (P = 0.15). No serious adverse events occurred. The new AHCL system demonstrated safety and effectiveness in controlling day and night glucose levels.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...