Background/Aims:
Endoscopic ultrasound-guided liver biopsy (EUS-LB) is an effective and safe method of procuring liver tissue. The aims of this study were to assess and compare the outcomes and tissue adequacy of a single-pass, single-actuation, wet suction technique between 19 G and 22 G needles in patients undergoing EUS-LB.
Methods:
We performed a prospective case series study of 20 patients undergoing EUS-LB at a single center between September 2017 and April 2020. The primary objective was to evaluate differences in sample adequacy via a single actuation wet suction technique between a 19 G core needle and a 22 G core needle. Adequacy was gauged by cumulative core biopsy length and the number of portal tracts visualized.
Results:
The 19 G needle provided a longer core length (2.5 cm vs. 1.2 cm, p<0.0001), more complete portal tracts (5.8 vs. 1.7, p<0.0001), more total tracts (8.8 vs. 3, p<0.0001), and a longer, intact, fragment length (0.75 cm vs. 0.32 cm, p<0.0006). The 19 G needle was superior in providing adequate (60% vs. 5%, p<0.001) and diagnostic pathologic samples (85% vs. 10%, p<0.001).
Conclusion:
A single-pass, single-actuation, wet suction technique using a 19 G needle is superior to that using a 22 G needle for tissue acquisition and sample adequacy in EUS-LB.
More Related Videos
07:44Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
10:19Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...