Related Experiment Video
Updated: Nov 30, 2025

A Dual-Functional Electroactive Filter Towards Simultaneously SbIII Oxidation and Sequestration
Published on: December 5, 2019
Selenite and selenate removal in a permeable flow-through bioelectrochemical barrier
Louis-B Jugnia1, Dominic Manno1, Abraham Gomez Vidales1
1National Research Council Canada, 6100 Royalmount Avenue, Montreal, Quebec H4P 2R2, Canada.
Abstract:
This study demonstrated the removal of selenite and selenate in flow-through permeable bioelectrochemical barriers (microbial electrolysis cells, MECs). The bioelectrochemical barriers consisted of cathode and anode electrode compartments filled with granular carbon or metallurgical coke. A voltage of 1.4 V was applied to the electrodes to enable the bioelectrochemical removal of selenium species. For comparison, a similarly designed permeable anaerobic biobarrier filled with granular carbon was operated without voltage. All biobarrier setups were fed with water containing up to 5,000 µg L-1 of either selenite or selenate and 70 mg L-1 of acetate as a source of organic carbon. Significant removal of selenite and selenate was observed in MEC experimental setups, reaching 99.5-99.8% over the course of the experiment, while in the anaerobic biobarrier the removal efficiency did not exceed 88%. By simultaneously operating several setups and changing operating parameters (selenium species, influent Se and acetate concentrations, etc.) we demonstrated enhanced removal of Se species under bioelectrochemical conditions.