Exploiting the unique specialty of hydrazone functionality: Synthesis of a highly sensitive UV-Vis active

Mudeha Shafat Khan1, Romana Khanam1, Sajad Ahmad Bhat1

  • 1Department of Chemistry, University of Kashmir, Hazratbal Srinagar 190006, India.

Related Concept Videos

UV–Vis Spectroscopy of Conjugated Systems01:32

UV–Vis Spectroscopy of Conjugated Systems

Organic compounds with conjugated double bonds show strong absorption features in the UV–visible region of the electromagnetic spectrum attributed to π → π* electronic excitations. Generally, a UV–vis absorption spectrum is recorded as a plot of absorbance vs wavelength. The wavelength of maximum absorbance, which manifests as a peak in the absorption spectrum, is denoted as λmax.
One of the factors influencing λmax is the extent of conjugation in...
7.9K
Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the para...
3.4K
Labeling DNA Probes03:31

Labeling DNA Probes

DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
8.9K
UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
2.8K
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview01:02

Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview

Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material,  molecules absorb light depending on the energy required for...
4.0K
Diazonium Group Substitution with Halogens and Cyanide: Sandmeyer and Schiemann Reactions01:20

Diazonium Group Substitution with Halogens and Cyanide: Sandmeyer and Schiemann Reactions

Arenediazonium substitution reactions occur when the diazonium group is substituted by various functional groups such as halides, hydroxyl, nitrile, etc. For instance, arenediazonium salts react with copper(I) salts of chloride, bromide, or cyanide to form corresponding aryl chlorides, bromides, and nitriles. These reactions are named Sandmeyer reactions. Although the mechanism of this reaction is complicated, as illustrated in Figure 1, they are believed to progress via an aryl copper...