Related Experiment Video
Updated: Nov 30, 2025

Research and Development of High-performance Explosives
Published on: February 20, 2016
Optimizing the Use of Phase Change Material Vests Worn During Explosives Ordnance Disposal Operations in Hot
Sarah Lee Davey1, Ben James Lee1, Mark Smith1
1Occupational and Environmental Physiology Group, Centre for Sport, Exercise and Life Sciences (CSELS), Faculty of Health and Life Sciences, Coventry University, Coventry, United Kingdom.
Abstract:
Phase change material (PCM) cooling garments' efficacy is limited by the duration of cooling provided. The purpose of this study was to evaluate the effect of replacing a PCM vest during a rest period on physiological and perceptual responses during explosive ordnance disposal (EOD) related activity. Six non-heat acclimated males undertook three trials (consisting of 2 × 3 × 16.5 min activity cycles interspersed with one 10 min rest period) in 40°C, 12% relative humidity whilst wearing a ≈38 kg EOD suit. Participants did not wear a PCM cooling vest (NoPCM); wore one PCM vest throughout (PCM1) or changed the PCM vest in the 10 min rest period (PCM2). Rectal temperature (T ), mean skin temperature (T ), heart rate (HR), Physiological Strain Index (PSI), ratings of perceived exertion, temperature sensation and thermal comfort were compared at the end of each activity cycle and at the end of the trial. Data displayed as mean [95% CI]. After the rest period, a rise in T was attenuated in PCM2 compared to NoPCM and PCM1 (-0.57 [-0.95, -0.20]°C and -0.46 [-0.81, -0.11]°C, respectively). A rise in HR and T was also attenuated in PCM2 compared to NoPCM and PCM1 (-23 [-29, -16] beats⋅min-1 and -17 [-28, -6.0] beats⋅min-1; -0.61 [-1.21, -0.10]°C and -0.89 [-1.37, -0.42]°C, respectively). Resulting in PSI being lower in PCM2 compared to NoPCM and PCM1 (-2.2 [-3.1, -1.4] and -0.8 [-1.3,-0.4], respectively). More favorable perceptions were also observed in PCM2 vs. both NoPCM and PCM1 (p < 0.01). Thermal perceptual measures were similar between NoPCM and PCM1 and the rise in T after the rest period tended to be greater in PCM1 than NoPCM. These findings suggest that replacing a PCM vest better attenuates rises in both physiological and perceptual strain compared to when a PCM vest is not replaced. Furthermore, not replacing a PCM vest that has exhausted its cooling capacity, can increase the level of heat strain experienced by the wearer.
Related Concept Videos
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Hot Weather Concreting
Mitigating the heat increase in concrete can be economically achieved by shading aggregate stockpiles to prevent heating from solar radiation,...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...
Phase Transitions: Sublimation and Deposition
States of Matter and Phase Changes
Phase Transitions: Vaporization and Condensation