Related Experiment Video
Updated: Nov 30, 2025

Comparison of Three Clinical Stereoscopic Methods for Measuring Binocular Visual Function During Amblyopic Treatment in Unilateral Amblyopia
Published on: September 27, 2024
Multicenter review of impression-based scleral devices
Amy Nau1, Ellen S Shorter2, Jennifer S Harthan3
1Korb & Associates, Boston, MA, USA; New England College of Optometry, Boston, MA, USA.
Impression-based scleral devices offer successful visual and therapeutic outcomes for patients with complex eye conditions, especially those who failed with standard scleral lenses.
Area of Science:
- Ophthalmology
- Optometry
- Contact Lens Technology
Background:
- Anterior segment diseases often present complex challenges for vision management.
- Standard scleral lenses may not be suitable for all patients with severe ocular surface conditions or corneal irregularities.
- Impression-based scleral devices represent an alternative approach for managing challenging cases.
Purpose of the Study:
- To evaluate the outcomes of impression-based scleral devices in managing anterior segment diseases.
- To assess the efficacy and patient success rates with this specialized lens type.
Main Methods:
- A retrospective chart review was conducted on patients fitted with impression-based scleral devices between January 2013 and June 2019.
- Data collected included patient demographics, indications for use, visual and physiological outcomes, fitting process details, and device survival.
- Patients with prior unsuccessful attempts with standard scleral lenses were specifically analyzed.
Main Results:
- Forty-four patients (70 eyes) were included, with primary indications being corneal irregularity and ocular surface disease.
- A significant improvement in visual acuity was observed with impression-based devices compared to habitual correction (p < 0.001).
- Successful fitting, including haptic alignment (74%) and limbal clearance (83%), was achieved in a majority of cases, with low discontinuation rates due to complications.
Conclusions:
- Impression-based scleral devices provide a viable solution for patients with complex eye diseases who have not succeeded with conventional scleral lenses.
- These devices can lead to significant visual and therapeutic success in challenging ophthalmic cases.