Related Experiment Video
Updated: Nov 30, 2025

Three-Dimensional Reconstruction of Orbital Fractures
Published on: May 16, 2025
Development and application of the average pelvic shape in virtual pelvic fracture reconstruction
Maha S Ead1, Mehrdad Palizi2, Jacob L Jaremko3
1Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada.
Background:
With unilateral pelvic fractures, the contralateral hemipelvis can be used as a template in virtual reconstruction; however, this cannot be applied for bilateral fractures. Therefore, statistical shape modelling was used to build average pelvic shapes that can serve as templates when reconstructing bilaterally fractured pelvises.
Methods:
Four average shape models were created for male and female, left and right hemipelves from 20 male and 20 female subjects. They were used as templates to reconstruct eight unilaterally fractured pelvises.
Results:
The average root-mean-square of deviations between the reconstructed and intact hemipelves was 1.46 ± 0.32 mm, which is less than the 2 mm threshold for causing hip joint complications.
Conclusion:
This indicates that the reconstructions are reliable and the average shape models can be used to reconstruct bilaterally fractured pelvises. The proposed technique can potentially provide quick and accurate treatment plans for pelvic fracture patients, which is necessary for recovery.