Related Experiment Video
Updated: Nov 30, 2025

A Method for the Measurement of Salivary Gland Function in Mice
Published on: January 25, 2018
[Research on consistency of different measurement methods for saliva 1,5-anhydroglucitol]
1Department of Endocrinology and Metabolism, Shanghai Jiao Tong University Affiliated Sixth People's Hospital, Shanghai Clinical Center for Diabetes, Shanghai 200233, China.
Abstract:
Objective: To evaluate the consistency of different measurement methods of saliva 1,5-anhydroglucitol (1,5-AG) in different glucose metabolism populations. Methods: From January 2018 to June 2019, 175 healthy volunteers (21-65 years, 58 males and 117 females) with normal glucose tolerance (NGT) and 80 diabetic patients (18-70 years, 44 males and 36 females) were enrolled in Shanghai Jiao Tong University Affiliated Sixth People's Hospital. Saliva was collected by saliva collection tube, and 1,5-AG was measured using both enzymatic and mass spectrometry methods. Serum 1,5-AG was determined by enzymatic method. Results: In NGT subjects, both serum and saliva 1,5-AG levels detected by enzymatic method were positively correlated with the saliva 1,5-AG levels detected by liquid chromatography-mass spectrometry (r=0.247 and 0.523, respectively, both P<0.05). However, there was no significant correlation between saliva and serum 1,5-AG levels detected by enzymatic method (r=-0.074, P=0.333). In diabetic patients, both serum and saliva 1,5-AG levels detected by enzymatic method were positively correlated with the saliva 1,5-AG levels detected by gas chromatography-mass spectrometry (r=0.284 and 0.423, respectively, both P<0.05). However, there was no significant correlation between saliva and serum 1,5-AG levels detected by enzymatic method (r=-0.079, P=0.487). Conclusions: Both serum and saliva 1,5-AG levels detected by enzymatic method have a good consistency with saliva 1,5-AG levels detected by mass spectrometry method. The saliva and serum 1,5-AG levels detected by enzymatic method are not well correlated, and thus the enzymatic detection of saliva 1,5-AG needs further improvement in clinical practice.
More Related Videos
08:25Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016