Related Experiment Video
Updated: Nov 29, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Resonance Raman Spectroscopy Derived Tissue Hemoglobin Oxygen Saturation in Critically Ill and Injured Patients
Mohamad H Tiba1,2, Abdelrahman B Awad1,2, Amanda Pennington1,2
1Department of Emergency Medicine, University of Michigan, Ann Arbor, Michigan.
Background:
In this study, we examined the ability of resonance Raman spectroscopy to measure tissue hemoglobin oxygenation (R-StO2) noninvasively in critically ill patients and compared its performance with conventional central venous hemoglobin oxygen saturation (ScvO2).
Methods:
Critically ill patients (n = 138) with an indwelling central venous or pulmonary artery catheter in place were consented and recruited. R-StO2 measurements were obtained by placing a sensor inside the mouth on the buccal mucosa. R-StO2 was measured continuously for 5 min. Blood samples were drawn from the distal port of the indwelling central venous catheter or proximal port of the pulmonary artery catheter at the end of the test period to measure ScvO2 using standard co-oximetry analyzer. A regression algorithm was used to calculate the R-StO2 based on the observed spectra.
Results:
Mean (SD) of pooled R-StO2 and ScvO2 were 64(7.6) % and 65(9.2) % respectively. A paired t test showed no significant difference between R-StO2 and ScvO2 with a mean(SD) difference of -1(7.5) % (95% CI: -2.2, 0.3%) with a Clarke Error Grid demonstrating 84.8% of the data residing within the accurate and acceptable grids. Area under the receiver operator curve for R-StO2's was 0.8(0.029) (95% CI: 0.7, 0.9 P < 0.0001) at different thresholds of ScvO2 (≤60%, ≤65%, and ≤70%). Clinical adjudication by five clinicians to assess the utility of R-StO2 and ScvO2 yielded Fleiss' Kappa agreement of 0.45 (P < 0.00001).
Conclusions:
R-StO2 has the potential to predict ScvO2 with high precision and might serve as a faster, safer, and noninvasive surrogate to these measures.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Transport in the Blood
Hypoxia
Types of Hypoxia
There are four primary types of hypoxia, each resulting from a different cause:
1. Anemic hypoxia: This type occurs due to insufficient oxygen delivery caused by a lack of red blood cells (RBCs) or RBCs with abnormal or...