Background:
Tracheobronchial stents types, uses, techniques for deployment and extraction have practice variations around the world.
Methods:
We collected responses by sending an online survey of 8 questions to world interventional bronchology member societies and social media groups.
Results:
There were 269 respondents from 47 countries. Europe had 97 respondents from 22 countries. There were 8 respondents from Australia, 7 from Africa (3 countries) and 7 from 4 countries in South America (SA). North America (NA) had 72 respondents from 3 countries. Asia had 78 respondents from 14 countries. For stent placements 15% [41] used fiberoptic bronchoscope (FB) only. Rigid bronchoscopy (RB) was solely utilized by 38% [102]. Forty-six percent [123] used a combination of RB and FB (P value <0.00001). For stent extraction 13% [19] used FB alone, 57% [85] used RB, and 36% [54] used a combination of RB and FB (P value <0.00001). Placement of stents were 50.5% [135] only by direct visualization. Twenty-three percent [61] always used fluoroscopic guidance. Twenty-six-point-five percent [71] used fluoroscopy in certain cases (P value <0.00001). Sixty percent [162] decided stent sizing by measurements of stenotic and non-stenotic areas on radiology. Twelve percent [32] respondents used sizing devices. Sixty-five percent [177] used a ruler and bronchoscope to measure stenotic areas. Thirty-eight percent [104] used visual estimation and experience. Seven percent [19] used serial balloon dilatation size. To prevent clogging of stents, 22% [59] prescribed mucolytics. Seventy-three percent [195] nebulized saline, 26% [70] had Mucomyst Nebulization, 24% [65] Nebulized bronchodilators and other methods 11% [30] were advised. Covered self-expandable metal stents (SEMS) 44% was the commonest type of stent used around the world. Silicone stents 37%, Y stents 15%, uncovered SEMS 12%, Montgomery T tube 5% followed. Polyflex stents 3% and custom-made stents 3% were least used. Biodegradable stents were used by 7.5%, and not used by 92.5%.
Conclusions:
Tracheobronchial stent practice norms have slowly evolved, but its practice variations lack uniformity, and have sparse evidence-based studies for its direction.
Related Concept Videos
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques