Related Experiment Video
Updated: Nov 29, 2025

Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound 30/45MHZ System
Published on: May 5, 2018
[Artificial intelligence technology in cardiac auscultation screening for congenital heart disease: present and
Abstract:
The electronic stethoscope combined with artificial intelligence (AI) technology has realized the digital acquisition of heart sounds and intelligent identification of congenital heart disease, which provides objective basis for heart sound auscultation and improves the accuracy of congenital heart disease diagnosis. At the present stage, the AI based cardiac auscultation technique mainly focuses on the research of AI algorithms, and the researchers have designed and summarized a variety of effective algorithms based on the characteristics of cardiac audio data, among which the mel-frequency cepstral coefficients (MFCC) is the most effective one, and widely used in the cardiac auscultation. However, the current cardiac sound analysis techniques are based on specific data sets, and have not been validated in clinic, so the performance of algorithms need to be further verified. The lack of heart sound data, especially the high-quality, standardized, publicly available heart sound database with disease labeling, further restricts the development of heart sound diagnostic analysis and its application in screening. Therefore, expert consensus is necessary in establishing an authoritative heart sound database and standardizing the heart sound auscultation screening process for congenital heart disease. This paper provides an overview of the research and application status of auscultation algorithm and hardware equipment based on AI in auscultation screening of congenital heart disease, and puts forward the problems to be solved in clinical application of AI auscultation screening technology.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:

