Ambient Temperature Self-Blowing Tannin-Humins Biofoams
Xinyi Chen1, Nathanael Guigo2, Antonio Pizzi1
1LERMAB, University of Lorraine, 27 rue Philippe Seguin, 88000 Epinal, France.
Abstract:
Ambient temperature self-blowing tannin-furanic foams have been prepared by substituting a great part-even a majority-of furfuryl alcohol with humins, a polyfuranic material derived from the acid treatment at high temperature of fructose. Closed-cell foams were prepared at room temperature and curing, while interconnected-cell foams were prepared at 80 °C and curing, this being due to the more vigorous evaporation of the solvent. These foams appear to present similar characteristics as other tannin-furanic foams based only on furfuryl alcohol. A series of tannin-humins-furfuryl alcohol oligomer structures have been defined indicating that all three reagents co-react. Humins appeared to react well with condensed tannins, even higher molecular weight humins species, and even at ambient temperature, but they react slower than furfuryl alcohol. This is due to their high average molecular weight and high viscosity, causing their reaction with other species to be diffusion controlled. Thus, small increases in solvent led to foams with less cracks and open structures. It showed that furfuryl alcohol appears to also have a role as a humins solvent, and not just as a co-reagent and self-polymerization heat generator for foam expansion and hardening. Stress-strain for the different foams showed a higher compressive strength for both the foam with the lowest and the highest proportion of humins, thus in the dominant proportions of either furfuryl alcohol or the humins. Thus, due to their slower reactivity as their proportion increases to a certain critical level, more of them do proportionally participate within the expansion/curing time of the foam to the reaction.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Thermosensation
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature and Thermal Equilibrium
The concept of temperature has evolved from the common concepts of hot and cold. The scientific definition of temperature explains more than just our sense of hot and cold. Temperature is operationally defined as the quantity measured with a thermometer. Furthermore, temperature is...
Air-entraining Agents


