Related Experiment Video
Updated: Nov 29, 2025

Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
Potential value of guard-wire technology in the interventional treatment for ostial coronary lesions
Xiaoqiong Wang1, Xuemei Zong2, Bingqiang Li1
1Department of Cardiology, The First People's Hospital of Pingdingshan City (The First Affiliated Hospital of Pingdingshan University), 117 Youyue Road, Weidong District, Pingdingshan, 467000, Henan Province, China.
Background:
To explore potential value of guard-wire technology during percutaneous coronary intervention (PCI) in patients with ostial coronary lesions.
Methods:
Patients, who underwent PCI, were collected between October 2011 and March 2017. Of the 141 patients, 63 (44.7%) have ostial lesions, and 78 (55.3%) have distal bifurcation sites. They were divided into group A (n = 71) and group B (n = 70). Group A received PCI after guard-wire technology. Group B were given balloon dilation and stent after placing guide wire through target lesion vessel. X-ray exposure time, contrast agent dosage, total PCI duration, pressure incarceration times, cases of malignant arrhythmia and cases of failed PCI of all patients were analyzed, respectively.
Results:
The general clinical characteristics includes patients age, sex ratio, the proportion of complications, smoking ratio and left ventricular ejection fraction of both groups was not significantly different. X-ray exposure time, contrast agent dosage, PCI total time, stent positioning time, pressure infestation frequency, arrhythmia frequency and complication number of group B were higher than those of group A. There is no case of malignant arrhythmia and case of failed PCI in group A, while there were five malignant arrhythmia and four failed PCI in group B. Contrast agent dosage and cases of failed PCI increased in group B compared with group A.
Conclusion:
The guard wire technology is safer and more feasible to patients with ostial coronary lesions who underwent PCI.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Coronary Artery Disease V: Interprofessional Care
Cardiac Catheterization IV: Nursing Management