Related Experiment Video
Updated: Nov 29, 2025

Automation of a Positron-emission Tomography PET Radiotracer Synthesis Protocol for Clinical Production
Published on: October 26, 2018
Fully Automated Radiosynthesis of [11C]Guanidines for Cardiac PET Imaging
Austin Y Zhao1, Allen F Brooks1, David M Raffel1
1Department of Radiology, University of Michigan, Ann Arbor Michigan 48109, United States.
Abstract:
Radiolabeled guanidines such as meta-iodobenzylguanidine (MIBG) find utility in nuclear medicine as both diagnostic imaging agents and radiotherapeutics and, over the years, numerous methods for incorporating radionuclides into guanidines have been developed. In connection with a project developing new positron emission tomography (PET) radiotracers for cardiac sympathetic nerve density, we had cause to prepare [11C]3F-PHPOG. However, it quickly became apparent that radiolabeling of guanidine scaffolds with carbon-11 has remained challenging, and historical methods lack compatibility with modern automated radiochemistry synthesis platforms and current Good Manufacturing Practice (cGMP) requirements. To address this challenge, we report a new automated method for radiolabeling guanidines with carbon-11. The method was used to prepare a series of [11C]guanidines in good radiochemical yield (8-76% by radio-HPLC) and was found to have broad substrate scope and tolerance of unprotected OH and NH functional groups. The method was used to synthesize [11C]3F-PHPOG for preclinical imaging, and suitability of the radiotracer for preclinical use was demonstrated through preliminary cardiac PET in New Zealand white rabbits which revealed good cardiac uptake and expected retention in the heart.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

![Technical Aspect of the Automated Synthesis and Real-Time Kinetic Evaluation of [11C]SNAP-7941](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F59557.jpg&w=3840&q=50)