Related Experiment Video
Updated: Nov 29, 2025

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Py-FTIR-GC/MS Analysis of Volatile Products of Automobile Shredder Residue Pyrolysis
1School of Mechanical Engineering, Shanghai Jiao Tong University, No. 800, Dongchuan Rd., Shanghai 200240, China.
Abstract:
Automobile shredder residue (ASR) pyrolysis produces solid, liquid, and gaseous products, particularly pyrolysis oil and gas, which could be used as renewable alternative energy resources. Due to the primary pyrolysis reaction not being complete, the yield of gaseous product is low. The pyrolysis tar comprises chemically unstable volatiles before condensing into liquid. Understanding the characteristics of volatile products will aid the design and improvement of subsequent processes. In order to accurately analyze the chemical characteristics and yields of volatile products of ASR primary pyrolysis, TG-FTIR-GC/MS analysis technology was used. According to the analysis results of the Gram-Schmidt profiles, the 3D stack plots, and GC/MS chromatograms of MixASR, ASR, and its main components, the major pyrolytic products of ASR included alkanes, olefins, and alcohols, and both had dense and indistinguishable weak peaks in the wavenumber range of 1900-1400 cm-1. Many of these products have unstable or weaker chemical bonds, such as =CH-, =CH2, -C=C-, and -C=CH2. Hence, more syngas with higher heating values can be obtained with further catalytic pyrolysis gasification, steam gasification, or higher temperature pyrolysis.
More Related Videos
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Aromatic Compound Fragmentation
Gas Chromatography: Types of Detectors-II
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Mass Spectrometry: Branched Alkane Fragmentation