Related Experiment Video
Updated: Nov 29, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Arytenoid Dislocation and Vocal Cord Immobility After Emergent Fiberoptic Intubation: A Case Report
1is a staff nurse anesthetist at the University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania.
Abstract:
This case report describes a right arytenoid dislocation after emergency fiberoptic nasotracheal intubation in a patient with angioedema. The patient returned to the emergency department multiple times with classic symptoms of arytenoid dislocation, complicated by resultant postinjury laryngeal edema and poorly controlled laryngopharyngeal reflux. The arytenoid injury was not initially recognized, which delayed treatment. Several months later, intraoperative assessment was done because of continued symptoms suspicious for laryngeal injury, resulting in a diagnosis of right cricoarytenoid joint fixation resulting from prior intubation trauma. Because of delayed diagnosis and treatment, severe cricoarytenoid joint scarring and fixation prevented repositioning of the arytenoid and improvement in laryngeal function. Discussion of this case includes a review of the anatomy and function of the arytenoid and cricoarytenoid joint, along with factors that increase and decrease joint stability and risk of injury. The etiology of arytenoid dislocation is described, along with suspected mechanisms of injury in anterior vs posterior and right vs left dislocations. Classic symptoms, the importance of early identification, and treatment options are also discussed.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...