Related Experiment Video
Updated: Nov 29, 2025

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Diaphragm Thickening During Venoarterial Extracorporeal Membrane Oxygenation Weaning: An Observational Prospective
Pierre Henri Moury1, Romain Zunarelli2, Sébastien Bailly3
1Pôle Anesthésie-Réanimation, CHU Grenoble Alpes, Grenoble, France; HP2 Laboratory, Grenoble Alpes University, Grenoble, France; Réanimation, CHT Gaston-Bourret Nouméa, Nouvelle-Calédonie, France.
Objectives:
The respiratory workload, according to the diaphragm thickening fraction (TF) during sweep gas flow (SGF), decrease during weaning from venoarterial extracorporeal membrane oxygenation (VA ECMO) was evaluated for the present study.
Design:
Prospective observational study.
Setting:
Monocentric.
Participants:
Patients were included if they were suitable for a first VA ECMO weaning trial and were breathing spontaneously.
Interventions:
SGF was set for 15 minutes when the TF was measured at 4 L/min, 2 L/min, and 1 L/min, with a 10-minute return to baseline between each step. Mechanical ventilation, when required, was set to pressure-support ventilation mode with 7 cmH2O (pressure support) and a positive end-expiratory pressure of 0 cmH2O. Diaphragm ultrasound was used to assess the TF at the end of each step. Demographics, left ventricular ejection fraction (LVEF), and outcome were collected.
Measurements And Main Results:
Fifteen patients were included. Ten patients were extubated, and five were ventilated. TF values were 6.3% [0-10] at 4 L/min, 13.3% [10-26] at 2 L/min, and 26.7% [22-44] at 1 L/min (analysis of variance: p < 0.001 between 4 L/min and 2 L/min and p = 0.03 between 2 L/min and 1 L/min). TF did not differ whether patients were or were not ventilated or whether they were or were not weaned successfully from ECMO. TF was correlated with LVEF at 1 L/min SGF (Pearson R 0.67 [0.21-0.88]; p = 0.009) and at 2 L/min (R 0.7 [0.27-0.89]; p = 0.005) but not at 4 L/min. SGF mitigated the relationship between LVEF and TF (analysis of covariance: p < 0.005).
Conclusions:
Diaphragm TF was related to the SGF of the venoarterial ECMO settings and LVEF at the time of weaning.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Acute Respiratory Failure-III
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include: