High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
Optimizing and applying high-resolution, in-line laboratory phase-contrast X-ray imaging for low-density material
1Center for X-ray Analytics, Department Materials Meet Life, Swiss Federal Laboratories for Material Science and Technology, Empa, Überlandstrasse 129, Dübendorf, Switzerland.
Abstract:
In-line, or propagation-based phase-contrast X-ray imaging (PBI) is an attractive alternative to the attenuation-based modality for low-density, soft samples showing low attenuation contrast. With the growing availability of micro- and nano-focus X-ray tubes, the method is increasingly applied in the laboratory. Here, we discuss the technique and demonstrate its advantages for selected low-density, low attenuation material samples using a lab-based micro- and nano-computed tomography systems Easytom XL Ultra, providing micron and sub-micron range resolution PBI images. We demonstrate a multi-step optimization of the lab-based PBI technique on our scanner that includes choosing the optimal detector-source hardware combination available in the setup, then optimizing the imaging geometry and finally the phase retrieval process through a parametric study. We point out and elaborate on the effect of noise correlation and texturing due to phase retrieval. We demonstrate the overall benefits of using the phase image and the phase retrieval for the selected samples such as improved image quality, increased contrast-to-noise ratio while only marginally influencing the spatial resolution. The improvement in image quality also enables further image processing steps for detailed structural analysis of the samples, which would be much more complicated if not impossible based on the transmission image.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...