Hydrogen-peroxide-based low-temperature sterilization is a new sterilization technology for temperature-dependent medical devices. The effect of the process parameters of hydrogen-peroxide-based sterilizer on the sterilization performance of process challenge devices (PCDs) needs to be investigated. Sterilant amount, operating temperature, vacuum pressure, diffusion time, and chamber loading of the sterilizer on the sterilization performance of PCDs were adjusted. Seven PCDs with various morphologies and material containing biological indicators (BI) (EZTest, Geobacillus stearothermophilus) were used to evaluate the sterilization performance. The sterilization success rates of PCDs were 86, 71, and 57% with controlled temperature and pressure, diffusion time, and sterilant volume injection, respectively. The PCD material and structure also obviously affected sterilization performance. The sterilization of PCD A is the least successful for all parameters. Meanwhile, the sterilization of PCD B was influenced by the diffusion time and the sterilant injection volume. PCD B and PCD C were successfully sterilized by controlling the temperature and pressure. The weights and volume of the sterilization loading chamber resulted in a different sterilization performance. Sterilization performances of PCD 1, PCD 2, and PCD 3 were <70, <90, and 100%, respectively. Sterilant volume, sterilant diffusion time, pressure, temperature, PCD types, and chamber loading were proven to be important process parameters of sterilizer that affect the sterilization performance of vaporized-hydrogen-peroxide-based sterilizers.
More Related Videos
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Physical Methods for Controlling Microbial Growth: Temperature
Methods for Controlling Microbial Growth