Related Experiment Video
Updated: Nov 29, 2025

Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Prominent eustachian valve: An uncommon cause of a common problem during extracorporeal membrane oxygenation support
Duvuru Ram1, Michael Gillham2, Amul K Sibal1
1Green Lane Cardiothoracic Unit, Auckland City Hospital, Auckland, New Zealand.
Abstract:
Suck down events in an extracorporeal membrane oxygenation (ECMO) circuit, due to vein wall being suctioned onto the cannula inflow ports, lead to low circuit flows. These low flow states can be reversed with fluid administration. We present a patient with a prominent eustachian valve (EV) which was encountered while managing the patient on ECMO post lung transplantation for pleuroparenchymal fibroelastosis. We hypothesize that presence of a prominent EV can induce suck down events and needs to be recognized in the differential diagnosis of this problem. This case adds to the literature to increase the awareness of this rare but significant problem.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...