Related Experiment Video
Updated: Nov 29, 2025

The 4-vessel Sampling Approach to Integrative Studies of Human Placental Physiology In Vivo
Published on: August 2, 2017
The effects of time and temperature on umbilical cord gas analysis
Isabella Fan1, Liran Hiersch2,3, Yekaterina Belov2,3
1Faculty of Medicine, University of Toronto, Toronto, Canada.
Objective:
Our objective was to evaluate the effects of time and temperature on umbilical-cord blood analysis.
Methods:
This prospective study included the term spontaneous vaginal deliveries. One venous and seven arterial samples were drawn from each umbilical cord within 5 min from delivery. Three samples were immediately refrigerated (3 °C), while all other samples were stored at room temperature (23-26 °C). Samples were analyzed in pairs (refrigerated and room-temperature samples) at 0, 20, 40, and 60 min after delivery for pH and lactate levels. Repeated-measures analysis using a generalized linear model was used to compare the change in pH and lactate values over time.
Results:
518 samples from 74 women were analyzed. The mean gestational age was 39.1 ± 1.1 weeks. All neonates had an Apgar score of ≥9 in the 1st and 5th minutes. Mean arterial pH and lactate levels at delivery (time 0) were 7.32 ± 0.07 and 4.00 ± 1.36 mmol/L, respectively. Over time, a statistically significant decrease in pH and a reciprocal increase in lactate levels were observed. The mean change in arterial pH following 60 min was 0.021 ± 0.028 (room-temperature) and 0.016 ± 0.023 (refrigerated); p < 0.001. Compared to pH, a greater change was demonstrated in lactate levels over time; the mean change in lactate following 60 min was -0.896 ± 0.535 (room temperature) and -0.512 ± 0.450 mmol/L (refrigerated). Temperature significantly altered both pH and lactate levels, but lactate levels were altered at earlier time points.
Conclusion:
Both time and temperature have significant effects on cord blood analysis. Yet, these changes are minor and may not have any clinical significance unless in extreme cases in which medicolegal aspects emerge.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Gas Thermometers and the Kelvin Scale
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...