Bronchial Thermoplasty: A Novel Therapeutic Approach to Severe Asthma
Published on: November 4, 2010
Bronchial thermoplasty reduces ventilation heterogeneity measured by multiple breath nitrogen washout
David Langton1,2, Kim Bennetts3, Francis Thien4,5
1Department of Thoracic Medicine, Frankston Hospital, Peninsula Health, 2 Hastings Road, Frankston, VIC, 3199, Australia. davidlangton@phcn.vic.gov.au.
Background:
Despite demonstrated symptomatic benefit from bronchial thermoplasty (BT), the underlying pathophysiological benefits have been uncertain. The purpose of the present study was to relate clinical benefit after BT to changes in lung physiology, focusing on ventilation homogeneity assessed using multiple breath nitrogen washout (MBNW), and how this may be affected by changes in airway volume and resistance.
Methods:
Consecutive patients (n = 21) with severe asthma scheduled for BT, were evaluated at baseline, 6 weeks and 6 months after completion of treatment. Assessments included the Asthma Control Questionnaire (ACQ), medication usage, exacerbation frequency, spirometry, plethysmography and MBNW. Eighteen of these patients underwent detailed CT evaluation for the estimation of airway volume at baseline and then after the left lung had received BT treatment but prior to right lung treatment. Data are mean ± STDEV.
Results:
Patients responded to BT with an improvement in ACQ from 3.4 ± 0.8 at baseline to 2.0 ± 1.1 at 6 months (p < 0.001). Steroid requiring exacerbations fell from 3.1 ± 2.9 in the 6 months prior to BT to 1.4 ± 1.7 following BT (p < 0.001). Significant reductions in maintenance oral steroid dosing and short acting beta agonist use were observed. Airway volume measured by CT scanning significantly increased after treatment. The FEV1 improved from 1.34 ± 0.65 l to 1.52 ± 0.76 l (p = 0.024). The Residual Volume fell from 2.87 ± 0.89 l to 2.71 ± 0.93 l (p = 0.008) and Total Airway Resistance (Raw) from 10.58 ± 6.56 to 7.64 ± 3.74 cmH2O.s.l-1 (p = 0.020). The Lung Clearance Index (LCI) was 187 ± 63% predicted at baseline and improved after treatment from 12.7 ± 3.3 to 11.8 ± 2.4 (p = 0.049). The improvement in LCI correlated with the improvement in Raw (r = 0.463, p = 0.035).
Conclusion:
Clinical benefit after BT is accompanied by improvements in lung physiology, including normalisation of lung homogeneity that seems to be driven by airway dilation and reduced resistance.
More Related Videos
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
08:23Author Spotlight: Advancing Lung Disease Research with Free-Breathing Hyperpolarized Xenon-129 MRI
Published on: November 10, 2023
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...
COPD: Management Using Bronchodilators and Corticosteroids
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...