[Generation of the Pseudo CT Image Based on the Deep Learning Technique Aimed for the Attenuation Correction of the
Ryohei Fukui1, Susumu Fujii2, Hiroki Ninomiya2
1Division of Clinical Radiology, Tottori University Hospital(Current address: Department of Radiological Technology, Graduate School of Health Sciences, Okayama University).
Abstract:
Computed tomography (CT) is used for the attenuation correction (AC) of [F-18] fluoro-deoxy-glucose positron emission tomography (PET) image. However, acquisition of a CT image for this purpose requires increasing the radiation dose of the patient. To generate a pseudo-image, a generative adversarial network (GAN) based on deep learning is adopted. The purpose of this study was to generate a pseudo-CT image, using a GAN, for the AC of the PET image, with the aim of reducing the dose of the patient. A set of approximately 15,000 no-AC PET and CT images was used as the training sample, and the CycleGAN was employed as the image generation model. The training samples were inputted in the CycleGAN, and the hyperparameters, i.e., the learning rate, batch size, and number of epochs were set to 0.0001, 1, and 300, respectively. A pseudo-PET image was obtained using a pseudo-CT image, which was used for the AC of the no-AC PET image. The coefficient of similarity between the real and generated pseudo-images was estimated using the peak signal-to-noise ratio (PSNR) , the structural similarity (SSIM), and the dice similarity coefficient (DSC). The average values of PSNR, SSIM, and DSC of the pseudo-CT were 31.0 dB, 0.87, and 0.89, and those of the pseudo-PET were 35.9 dB, 0.90, and 0.95, respectively. The AC for the whole-body PET image could be accomplished using the pseudo-CT image generated via the GAN. The proposed method would be established as the CT-less PET/CT examination.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
04:48Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...