Related Experiment Video
Updated: Nov 29, 2025

On-line Analysis of Nitrogen Containing Compounds in Complex Hydrocarbon Matrixes
Published on: August 5, 2016
Characterization of Nano-Gravimetric-Detector Response and Application to Petroleum Fluids up to C34
Laura Alonso Sobrado1, Matthieu Loriau2, Serge Junca3
1APIX Analytics, Miniparc Polytec, Immeuble Tramontane, 60 rue des Berges, 38000 Grenoble, France.
Abstract:
A nano-gravimetric detector (NGD) for gas chromatography is based on a nanoelectromechanical array of adsorbent-coated resonating double clamped beams. NGD is a concentration-sensitive detector and its sensitivity is analyte-dependent based on the affinity of the analyte with the porous layer coated on the NEMS surface. This affinity is also strongly related to the NGD temperature (NGD working temperature can be dynamically set up from 40 to 220 °C), so the sensitivity can be tuned through temperature detector control. An adsorption-desorption model was set up to characterize the NGD response on a large set of n-alkanes from C10 to C22 at different NGD temperatures. For fast identification of petroleum mixture based on chromatogram fingerprint, a general strategy for NGD temperature program design was developed leading to a constant relative response factor between 0.96 and 1.03 for all the alkanes, and then chromatograms are very similar to those obtained with a flame ionization detector (FID). The analysis of a real petroleum fluid was also performed and compared to FID results: quantitative results obtained for all the analytes were satisfactory according to precision (<5%) and accuracy (average relative error = 4.3%). Based on such temperature control strategy, NGD sensitivity and the dynamic linear range can be adjusted and detection limits at a picogram level can be easily achieved for all n-alkanes.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...