Related Experiment Video
Updated: Nov 29, 2025

Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Reconstruction of Optical Coherence Tomography Images Using Mixed Low Rank Approximation and Second Order Tensor
Abstract:
This paper proposes a mixed low-rank approximation and second-order tensor-based total variation (LRSOTTV) approach for the super-resolution and denoising of retinal optical coherence tomography (OCT) images through effective utilization of nonlocal spatial correlations and local smoothness properties. OCT imaging relies on interferometry, which explains why OCT images suffer from a high level of noise. In addition, data subsampling is conducted during OCT A-scan and B-scan acquisition. Therefore, using effective super-resolution algorithms is necessary for reconstructing high-resolution clean OCT images. In this paper, a low-rank regularization approach is proposed for exploiting nonlocal self-similarity prior to OCT image reconstruction. To benefit from the advantages of the redundancy of multi-slice OCT data, we construct a third-order tensor by extracting the nonlocal similar three-dimensional blocks and grouping them by applying the k-nearest-neighbor method. Next, the nuclear norm is used as a regularization term to shrink the singular values of the constructed tensor in the non-local correlation direction. Further, the regularization approaches of the first-order tensor-based total variation (FOTTV) and SOTTV are proposed for better preservation of retinal layers and suppression of artifacts in OCT images. The alternative direction method of multipliers (ADMM) technique is then used to solve the resulting optimization problem. Our experiments show that integrating SOTTV instead of FOTTV into a low-rank approximation model can achieve noticeably improved results. Our experimental results on the denoising and super-resolution of OCT images demonstrate that the proposed model can provide images whose numerical and visual qualities are higher than those obtained by using state-of-the-art methods.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Linear Approximation in Time Domain
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length,...
Reconstruction of Signal using Interpolation
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...