Evaluation of cuff deflation and inflation rates on a deep learning-based automatic blood pressure measurement
Fan Pan1, Peiyu He1, Fei Chen2
1College of Electronics and Information Engineering, Sichuan University, Chengdu.
Objective:
The aim of this study was to evaluate the performance of using a deep learning-based method for measuring SBPs and DBPs and the effects of cuff inflation and deflation rates on the deep learning-based blood pressure (BP) measurement (in comparison with the manual auscultatory method).
Methods:
Forty healthy subjects were recruited. SBP and DBP were measured under four conditions (i.e. standard deflation, fast deflation, slow inflation and fast inflation) using both our newly developed deep learning-based method and the reference manual auscultatory method. The BPs measured under each condition were compared between the two methods. The performance of using the deep learning-based method to measure BP changes was also evaluated.
Results:
There were no significant BP differences between the two methods (P > 0.05), except for the DBPs measured during the slow and fast inflation conditions. By applying the deep learning-based method, SBPs measured from fast deflation, slow inflation and fast inflation decreased significantly by 3.0, 3.5 and 4.7 mmHg (all P < 0.05), respectively, in comparison with the standard deflation condition. Whereas, corresponding DBPs measured from the slow and fast inflation conditions increased significantly by 5.0 and 6.8 mmHg, respectively (both P < 0.05). There were no significant differences in BP changes measured by the two methods in most cases (all P > 0.05, except for DBP change in the slow and fast inflation conditions).
Conclusion:
This study demonstrated that the deep learning-based method can achieve accurate BP measurement under the deflation and inflation conditions with different rates.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure