Related Experiment Video
Updated: Nov 28, 2025

Efficient SARS-CoV-2 Quantitative Reverse Transcriptase PCR Saliva Diagnostic Strategy utilizing Open-Source Pipetting Robots
Published on: February 11, 2022
Practical challenges to the clinical implementation of saliva for SARS-CoV-2 detection
Nancy Matic1,2, Aleksandra Stefanovic3,4, Victor Leung3,4
1Division of Medical Microbiology and Virology, Providence Health Care, St. Paul's Hospital, 1081 Burrard St., Vancouver, BC, V6Z 1Y6, Canada. nmatic@providencehealth.bc.ca.
Abstract:
Due to global shortages of flocked nasopharyngeal swabs and appropriate viral transport media during the COVID-19 pandemic, alternate diagnostic specimens for SARS-CoV-2 detection are sought. The accuracy and feasibility of saliva samples collected and transported without specialized collection devices or media were evaluated. Saliva demonstrated good concordance with paired nasopharyngeal swabs for SARS-CoV-2 detection in 67/74 cases (90.5%), though barriers to saliva collection were observed in long-term care residents and outbreak settings. SARS-CoV-2 RNA was stable in human saliva at room temperature for up to 48 h after initial specimen collection, informing appropriate transport time and conditions.