Dynamic Analysis and Experiment of 6-DOF Compliant Platform Based on Bridge-Type Amplifier

Chao Lin1, Shan Zheng1, Mingdong Jiang1

  • 1State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing 400030, China.

Micromachines
|November 26, 2020
PubMed

Related Concept Videos

Design Example: Strain Gauge Bridge or Wheatstone Bridge01:15

Design Example: Strain Gauge Bridge or Wheatstone Bridge

The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
739
Impact Loading on a Cantilever Beam01:13

Impact Loading on a Cantilever Beam

The analysis of a cantilever beam with a circular cross-section subjected to impact loading at its free end illustrates the conversion of potential energy from a dropped object into kinetic energy, which is then absorbed by the beam as strain energy. This process is crucial for understanding how materials behave under dynamic loads, which is important in fields such as construction and aerospace.
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
689
Beams with Unsymmetric Loadings01:17

Beams with Unsymmetric Loadings

Analyzing a supported beam under unsymmetrical loadings is essential in structural engineering to understand how beams respond to varied force distributions. This analysis involves calculating the deflection and identifying points where the slope of the beam is zero, which are crucial for ensuring structural stability and functionality.
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
292
Cascaded Op Amps01:16

Cascaded Op Amps

Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
910
Wheatstone Bridge01:29

Wheatstone Bridge

An ohmmeter is a resistance-measuring device. It works by applying a voltage to a resistor of unknown resistance and measuring the current across the resistor. The resistance value is deduced using Ohm's law. Usually, the standard configuration of an ohmmeter comprises a voltmeter or an ammeter. However, such configurations are limited in accuracy because the meters alter the voltage applied to the resistor and the current that flows through it.
Thus, for accurate resistance measurements, a...
946
Deformation of a Beam under Transverse Loading01:15

Deformation of a Beam under Transverse Loading

Understanding beam deflection, particularly for indeterminate beams with overhanging segments and multiple concentrated loads, is crucial for ensuring structural integrity and functionality. The process begins with constructing an accurate free-body diagram, which helps identify the forces and moments acting on the beam. This diagram is vital for visualizing how bending moments vary along the beam's length, influencing its curvature.
The insights from the bending moment diagram extend to...
551