Related Experiment Video
Updated: Jul 10, 2026

Colorimetric Paper-based Detection of Escherichia coli, Salmonella spp., and Listeria monocytogenes from Large Volumes of Agricultural Water
Published on: June 9, 2014
Evaluation of the 3M™ Petrifilm™ Rapid E. coli/Coliform Count Plate for the Enumeration of E. coli and Coliforms:
Patrick Bird1, Benjamin Bastin1, Nicole Klass1
1Q Laboratories, Inc, 1400 Harrison Ave, Cincinnati, OH 45214, USA.
Background:
The 3M™ Petrifilm™ Rapid E. coli/Coliform Count Plate is a selective and differential sample-ready-culture medium designed for the rapid enumeration of Escherichia coli (E. coli) and coliforms in the food and beverage industries.
Objective:
The 3M Petrifilm Rapid E. coli/Coliform Count Plate was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual (BAM) Chapter 4 Enumeration of Escherichia coli and the Coliform Bacteria, the International Organization of Standards (ISO) 4832:2006 Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms-Colony-count technique, and ISO 16649-2:2017 Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli-Part 2 Colony-count technique at 44 degrees C using bromo-4-chloro-3- indolyl beta-D-glucuronide methods for the enumeration of E. coli and coliforms in dry dog kibble.
Method:
The candidate method was evaluated using two diluents, Butterfield's phosphate buffered diluent and peptone salt solution, in a paired study design with each reference method in a multi-laboratory collaborative study following the current AOAC Validation Guidelines. Three target contamination levels and an uninoculated control level were evaluated.
Results:
The candidate and reference methods were not statistically different at each contamination level. Reproducibility values obtained during the collaborative study were similar between the candidate and reference methods.
Conclusion:
These results demonstrate that the candidate method is equivalent to the reference methods.
Highlight:
3M Petrifilm Rapid E. coli/Coliform Count Plate was recommended for Official First Action status for enumeration of E. coli and coliforms in a broad range of foods and environmental surfaces.