Related Experiment Video
Updated: Nov 28, 2025

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Ultrasound visualization of the vagus nerve for intraoperative neuromonitoring in thyroid surgery
Dana M Hartl1, Sophie Bidault2, Elizabeth Girard2
1Department of Surgery, Anesthesia and Interventional Medicine, Gustave Roussy Cancer Campus and University Paris-Saclay, Villejuif, Cedex, France. dana.hartl@gustaveroussy.fr.
Objective:
Localization of the vagus nerve is required during intraoperative neuromonitoring (IONM) for thyroid surgery in order to electromyographically verify the functional integrity of inferior laryngeal nerve and aim to reduce the risk of postoperative vocal fold paralysis. Classically, the vagus nerve courses within the carotid sheath between the common carotid artery and internal jugular vein, but anatomic variations have been described. Our aim was to compare preoperative ultrasound (US) and intraoperative localization of vagus nerve and to document anatomic variations.
Patients And Methods:
Retrospective study of patients undergoing thyroidectomy. The vagus nerve was identified 2 cm below the inferior border of the cricoid cartilage, on US performed 6 weeks prior to surgery; then, vagus nerve was identified surgically.
Results:
For 82 patients, on preoperative US, the right vagus nerve was in between, superficial, or deep to the vessels in 94%, 2.4%, and 3.6%, and on the left in 72%, 24.4%, and 3.6%. Intraoperatively, the right vagus was in between, superficial, or deep in 90%, 4%, and 6%, and on the left in 67%, 27%, and 6%. US correlated with surgery on the right in 79/82 (96%) and on the left in 78/82 (95%).
Conclusions:
To our knowledge, this is the first study directly comparing US and intraoperative findings. The US and surgical findings were identical in 95% on the left and 96% on the right The vagus nerve was superficial in 27% of cases on the left and 4% on the right. Identifying this anatomic variation preoperatively may facilitate IONM.
Key Points:
• Localization of the vagus nerve is necessary during thyroid surgery when using neuromonitoring for electromyographic testing of the inferior laryngeal nerve to reduce the risk of postoperative vocal fold paralysis. • The vagus nerve in the neck can be routinely visualized using ultrasound, and is generally in between the common carotid artery and the internal jugular vein. Its location on ultrasound corresponds very closely to that observed in vivo during surgery (95%). • At the level of the thyroid lobe, there is an anatomic variant with the vagus nerve superficial to the common carotid artery which is seen more often on the left than on the right.
More Related Videos
05:25Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...