Related Experiment Video
Updated: Nov 28, 2025

Applications of In Vivo Functional Testing of the Rat Tibialis Anterior for Evaluating Tissue Engineered Skeletal Muscle Repair
Published on: October 7, 2016
Proximal fibular nerve conduction studies to tibialis anterior: Optimal E2 (reference electrode) placement
1Department of Clinical Neurophysiology, Royal Melbourne Hospital, Parkville, Victoria, Australia.
Background:
Several E2 (reference electrode) positions are described for fibular (peroneal) nerve conduction studies to tibialis anterior (TA).
Methods:
This study compared the contribution of different E2 sites to the TA motor response, using remote referential recordings and different bipolar montages.
Results:
The medial knee contributes minimal electrical activity to the bipolar TA recordings, whereas tibial, ankle, and toe references resulted in very similar, moderate amplitude contributions consistent with far field potentials. These observations were very similar in controls and in patients with lower leg symptoms and signs.
Conclusions:
Standard montages using distal leg or foot E2 sites result in lower amplitudes with distortion arising from the E2 electrode, compared with the TA-Knee montage. Optimal measurement of the TA motor response is achieved using a medial knee reference, without compromising measures of fibular nerve conduction across the knee.