Role of a spanning plate as an internal fixator in complex distal radius fractures
Frank J P Beeres1, Rémy Liechti2, Björn-Christian Link2
1Klinik Orthopädie und Unfallchirurgie, Luzerner Kantonsspital Luzern, Spitalstrasse I, 6000, Luzern 16 I, Switzerland. frank.beeres@luks.ch.
Objective:
Minimally invasive temporary internal wrist arthrodesis as an alternative treatment method in complex distal radius fractures.
Indications:
Complex distal radius fractures with dorsal and/or palmar comminution and little to no reconstruction possibilities, radiocarpal ligamentous injury, need for early weight bearing through the affected wrist (walking aids).
Contraindications:
Complex hand injuries limiting the possibility to safely secure the plate at either the metacarpal or the radial shaft.
Surgical Technique:
Percutaneous or open reduction and fixation of the distal radius fracture. Determine the location for the two stab incisions under fluoroscopy; one over the distal radial diaphysis and one over the second or third metacarpal. A third incision over Lister's tubercle allows transposition of the extensor pollicis longus (EPL) tendon, excision of the posterior interosseous nerve and dorsal arthrotomy. Retrograde insertion of the spanning plate. Placement of a first nonlocking screw through the glide hole into the metacarpal shaft. Under traction, a proximal screw hole is filled with a nonlocking screw into the radial diaphysis. Tightening of the cortical screws under lateral fluoroscopic view. The remaining screw holes at both the distal and proximal ends of the plate are filled with locking screws. Layered wound closure.
Postoperative Management:
A removable wrist splint is worn during 2 weeks. Weight bearing through the injured wrist is immediately allowed. Removal of the spanning plate is scheduled at 3 months after radiographic evidence of fracture consolidation.
Results:
In total, twelve distal radius fractures were treated by dorsal spanning plate fixation between January 2018 and January 2019. Average age was 53.3 ± 24.5 years (range 22-95 years). Both 3.5 mm and 2.4/2.7 mm plates were used. All twelve fractures were healed after 3 months. The mean Disabilities of Arm, Shoulder and Hand (DASH) score was 36.4 (range 8.3-70.0). There was one EPL tendon rupture, one case with extensor tendon adhesions, one periosteosynthetic fracture of the radial shaft and one complex regional pain syndrome. There was no implant failure and no infection.
More Related Videos
10:09Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
