Related Experiment Video
Updated: Nov 28, 2025

Lung Rapid Recovery Procurement Combined with Abdominal Normothermic Regional Perfusion in Controlled Donation after Circulatory Death
Published on: August 15, 2022
Donor ventilation parameters as predictors for length of mechanical ventilation after lung transplantation: Results
Alberto Benazzo1, Stefan Schwarz1, Florian Frommlet2
1Division of Thoracic Surgery, Medical University of Vienna, Vienna, Austria.
Background:
The evaluation of donor lungs heavily depends on the subjective judgment of the retrieval surgeon. As a consequence, acceptance rates vary significantly among transplant centers. We aimed to determine donor ventilation parameters in a prospective study and test if they could be used as objective quality criteria during organ retrieval.
Methods:
A prospective evaluation of lung donors was performed in 3 transplant centers. Ventilation parameters were collected at the time of retrieval using a standardized ventilation protocol. Recipient length of mechanical ventilation (LMV) was defined as the primary end point, and collected data was used to build linear models predicting LMV.
Results:
In total, 166 donors were included in this study. Median LMV after transplantation was 32 hours (interquartile range: 20-63 hours). Peak inspiratory pressure and dynamic compliance (Cdyn) at the time of retrieval, but not the partial pressure of oxygen/fraction of inspired oxygen (P/F) ratio, correlated with recipient LMV in Spearman correlations (r = 0.280, p = 0.002; r = -0.245, p = 0.003; and r = 0.064, p = 0.432, respectively). Linear models were built to further evaluate the impact of donor ventilation parameters on LMV. The first model was based on donor P/F ratio, donor age, donor intubation time, donor smoking history, donor partial pressure of carbon dioxide, aspiration, chest trauma, and pathologic chest X-ray. This model performed poorly (multiple R-squared = 0.063). In a second model, donor ventilation parameters were included, and Cdyn was identified as the strongest predictor for LMV. The third model was extended by recipient factors, which significantly improved the robustness of the model (multiple R-squared = 0.293).
Conclusion:
In this prospective evaluation of donor lung parameters, currently used donor quality criteria poorly predicted recipient LMV. Our data suggest that Cdyn is a strong donor-bound parameter to predict short-term graft performance; however, recipient factors are similarly relevant.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...

