Related Experiment Video
Updated: Nov 28, 2025

Study on the Metabolism of Six Systemic Insecticides in a Newly Established Cell Suspension Culture Derived from Tea Camellia Sinensis L. Leaves
Published on: June 15, 2019
Development of Artificial Urine Certified Reference Material for Quantification of Neonicotinoid Insecticides
Takamitsu Otake1, Shoji F Nakayama2, Tomohiko Isobe2
1National Institute of Advanced Industrial Science and Technology, National Metrology Institute of Japan, 1-1-1 Umezono, Tsukuba, Ibaraki 305-8563, Japan.
Background:
Neonicotinoid insecticides (neonicotinoids) are widely used, however, they can negatively affect human health. Thus, neonicotinoids and their metabolites in human urine are analyzed globally to assess exposure levels and health risks. To properly assess the exposure levels and health risks, accurate analytical results are a necessity.
Objective:
This study aims to develop urine certified reference material (CRM), NMIJ CRM 7408-a, for the quantification of neonicotinoids.
Method:
To develop NMIJ CRM 7408-a, commercially available artificial urine was used as the raw material to which the target neonicotinoids were added. Analyses of neonicotinoids in NMIJ CRM 7408-a were carried out by isotope dilution mass spectrometry (IDMS).
Results:
Sample homogeneity was assessed, with the results showing that acetamiprid, clothianidin, thiacloprid, and thiamethoxam exhibited sufficiently homogeneous distributions in the material. The relative uncertainties due to inhomogeneity were 1.2-7.0%. The results obtained from long-term stability assessment indicated that the target neonicotinoids were stable. The relative uncertainties due to instability were 9.4-17.2% (for an expiry date of 21 months). The characterization for providing concentration values was carried out using one (clothianidin and thiacloprid) or two (acetamiprid and thiamethoxam) analytical methods. The certified values of the target neonicotinoids (acetamiprid, clothianidin, thiacloprid, and thiamethoxam) were 0.19-1.38 µg/kg.
Conclusions:
This is the first frozen artificial urine CRM in which neonicotinoids were quantified by IDMS and will be useful for evaluating the accuracy of analysis and validation of analytical methods for the determination of neonicotinoids in urine.
Highlights:
NMIJ CRM 7408-a, which has been certified for four neonicotinoids, was developed by NMIJ.
More Related Videos
08:49Vegetated Treatment Systems for Removing Contaminants Associated with Surface Water Toxicity in Agriculture and Urban Runoff
Published on: May 15, 2017
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023