Related Experiment Video
Updated: Nov 28, 2025

Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model
Published on: November 4, 2021
Onyx versus coil embolization for the treatment of type II endoleaks
Oonagh Scallan1, Stewart Kribs2, Adam H Power1
1Department of Vascular Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada.
Objective:
Little evidence is available supporting the optimal treatment of type II endoleaks associated with aortic sac growth. Previous studies have lacked comparisons between treatment methods and long-term follow-up. The purpose of the present study was to review our center's experience with the treatment of type II endoleaks comparing Onyx (a liquid embolization agent consisting of ethylene vinyl alcohol; Medtronic, Minneapolis, Minn) embolization and coil embolization.
Methods:
A retrospective review of prospectively collected data from a vascular surgery database was performed to identify all patients who had undergone embolization of a type II endoleak for aortic sac growth after endovascular aneurysm repair from 2005 to 2018. The Onyx and coil embolization groups were compared using univariate statistics.
Results:
A total of 58 patients had undergone 77 embolization procedures for type II endoleaks with either Onyx (27 patients; 37 procedures) or coils (31 patients; 40 procedures). The average aneurysm size at embolization was larger in the Onyx group (77.9 ± 15.1 mm) compared with coil embolization (73.4 ± 11.9 mm). The mean follow-up was 57 months for the Onyx group and 74 months for the coil embolization group. Of the 27 patients who had undergone Onyx embolization, 2 (7.4%) had required graft explantation compared with 5 of the 31 patients (16.1%) who had undergone coil embolization (P = .33). The results of the per-patient analysis showed that the coil embolization group had a significantly greater rate of the need for further reintervention compared with the Onyx group (55% vs 19%; P < .01). Clinical success was observed in 13 patients (48%) in the Onyx embolization group compared with 10 patients (32%) in the coil embolization group (P = .04). Two patients in each group had presented with secondary rupture of the aneurysm sac after attempted embolization.
Conclusions:
Type II endoleaks associated with sac growth treated with Onyx were less likely to require further reinterventions than were those treated with coil embolization. A trend was found toward a greater need for endovascular aneurysm repair explant after coil embolization. With a high rate of further reintervention and potential for sac rupture, diligent follow-up is required after attempted type II embolization, regardless of the technique used.
Related Concept Videos
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Esophageal Varices-I: Introduction
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Endocarditis IV: Nursing Management

