Related Experiment Video
Updated: Nov 28, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Analysis of stress distribution in lingual orthodontics system for effective en-masse retraction using various
Ashish Kushwah1, Mukesh Kumar2, Manish Goyal2
1Department of Orthodontics and Dentofacial Orthopaedics, Institute of Dental Education and Advance Studies, Gwalior, Madhya Pradesh, India.
Introduction:
The aims and objectives of this study were to evaluate the von Mises stress and principal stress distribution and displacement of anterior teeth in a lingual orthodontics system along the periodontal ligament and alveolar bone by various combinations of mini-implants and lever arm during en-masse retraction. Four 3-dimensional finite element (FE) models of the bilateral maxillary first premolar extraction cases were constructed.
Methods:
Lingual brackets were (0.018-in slots) positioned over the center of the clinical crown. In all 4 models, 150 g of retraction force was applied with the help of a nickel-titanium closed coil spring with different combinations of mini-implants and lever arm on each side. FE analysis was then performed to evaluate stress distribution, principal stress, von Mises stress, and displacement of the anterior teeth using ANSYS software (version 12.1; Ansys, Canonsburg, Pa). The FE study was enough to validate the analysis results obtained by software tools with FE simulation instead of experimental readings. Thus, statistical analysis was not required.
Results:
In this study, maximum tensile stresses were observed in the periodontal ligament at the mesial cervical region of the canine with values of 1.84 MPa, 2.02 MPa, 1.88 MPa, and 2.08 MPa for models 1-4, respectively. Maximum von Mises stress in alveolar bone was 8.05 MPa, 8.23 MPa, 8.19 MPa, and 8.37 MPa for models 1-4, respectively, which was within the optimum limit (135 MPa). Variable amounts of displacements like lingual crown tipping, lingual root tipping, and extrusion were observed in all the models. The 15-mm long lever arm models (models 2 and 4) showed a more controlled crown (0.015 mm) and root movement (0.004 mm) compared with 12-mm long lever arm models (models 1 and 3).
Conclusions:
In lingual orthodontics, controlled root movement increased as we increased the length of the lever arm. It was also concluded that the amount of increased controlled tipping found with the placement of the mini-implant was toward the palatal slope.
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Applications of Stress
The...
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to its distance...
Stability of structures
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...

