Evaluation Methods for the Measurement of Lower Leg Edema in Healthy Young Adults
Masahiro Nishimura1, Toshiaki Kato1, Sho Onodera2
1Division of Medical Science in Sports and Exercise, Department of Medical Education, School of Medicine, Faculty of Medicine, Tottori University, Tottori 680-8550, Japan.
Background:
In recent years, objective quantitative evaluations have become particularly important. Both qualitative and quantitative evaluations are also available for edema. It is thought that the technical problem of quantitative evaluation can be solved by using a simple and reproducible method. Several studies have evaluated various methods for measuring edema. Limitations, such as weaknesses, measurement complexity, and errors, have been identified. Therefore, this study aimed to consider a simple and effective measurement method for the quantitative evaluation of edema.
Methods:
This study was a prospective, observational study. The subjects were 15 healthy adults (2 male and 13 female). Measurements were performed on the subjects' right lower leg once in the morning and once in the afternoon, with a minimum interval of 4 hours.
Results:
The actual volume of the lower leg was correlated with all indices except the ultrasonic echo findings for subcutaneous tissue. The intra-subject and inter-subject reliabilities for the indices using digital images were very high. The lower leg volume was greater significantly in the afternoon from the morning.
Conclusion:
The leg circumference was measured by utilizing a tape, while the width and volume were measured by utilizing digital imaging suitable for quantitatively evaluating edema. Furthermore, swelling of the lower leg with time can occur in the absence of daily exercise.
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Pulse Assessment Sites
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pre-Procedural Guidelines for Assessing Blood Pressure