Related Experiment Video
Updated: Nov 28, 2025

Additive Manufacturing-Enabled Low-Cost Particle Detector
Published on: March 24, 2023
Statistics of a Sharp GP2Y Low-Cost Aerosol PM Sensor Output Signals
Klemen Bučar1,2,3, Jeanne Malet4, Luca Stabile5
1Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia.
Abstract:
In this work, we characterise the performance of a Sharp optical aerosol sensor model GP2Y1010AU0F. The sensor was exposed to different environments: to a clean room, to a controlled atmosphere with known aerosol size distribution and to the ambient atmosphere on a busy city street. During the exposure, the output waveforms of the sensor pulses were digitised, saved and a following offline analysis enabled us to study the behaviour of the sensor pulse-by-pulse. A linear response of the sensor on number concentration of the monosized dispersed PSL particles was shown together with an almost linear dependence on particle diameters in the 0.4 to 4 micrometer range. The gathered data about the sensor were used to predict its response to an ambient atmosphere, which was observed simultaneously with a calibrated optical particle counter.