Application of Shear Wave Sonoelastography in the Differential Diagnosis of Extra- and Intra-Thyroidal Ectopic Thymic
Magdalena Stasiak1, Zbigniew Adamczewski1,2, Renata Stawerska1,3
1Department of Endocrinology and Metabolic Diseases, Polish Mother's Memorial Hospital-Research Institute, 281/289 Rzgowska St., 93-338 Lodz, Poland.
The ultrasound (US) pattern of intrathyroidal ectopic thymus (IET) can resemble papillary thyroid carcinoma (PTC) while the extrathyroidal ectopic thymus (EET) can mimic pathological lymph nodes. Recently, the usefulness of strain elastography (SE) was demonstrated in the differential diagnosis, however this method has several limitations. The aim of the current study was to assess the usefulness of shear wave elastography (SWE) in this field. The US, SE, and SWE were performed in 31 children with 53 ectopic thymuses (ETs) and quantitative values of SWE parameters were calculated, so as to generate potential normative values of ET elasticity and of the shear wave ratio (SWR). The mean SWRIET was 0.89 ± 0.21 and the mean shear wave stiffness (SWS) was 7.47 ± 1.93 kPa. The mean SWREET was 0.84 ± 0.15 and the mean SWSEET was 11.28 ± 2.58 kPa. The results have proven that the stiffness of ETs is lower or equal to the thyroid's. SWE was demonstrated to be a useful diagnostic method for ET evaluation. Therefore, the application of SWE in ET diagnosis allows more accurate evaluation of ET-like lesions and, in many cases, allows one to avoid invasive procedures, simultaneously providing a precise monitoring method based on combined US and SWE evaluation.
The ultrasound (US) pattern of intrathyroidal ectopic thymus (IET) can resemble papillary thyroid carcinoma (PTC) while the extrathyroidal ectopic thymus (EET) can mimic pathological lymph nodes. Recently, the usefulness of strain elastography (SE) was demonstrated in the differential diagnosis, however this method has several limitations. The aim of the current study was to assess the usefulness of shear wave elastography (SWE) in this field. The US, SE, and SWE were performed in 31 children with 53 ectopic thymuses (ETs) and quantitative values of SWE parameters were calculated, so as to generate potential normative values of ET elasticity and of the shear wave ratio (SWR). The mean SWRIET was 0.89 ± 0.21 and the mean shear wave stiffness (SWS) was 7.47 ± 1.93 kPa. The mean SWREET was 0.84 ± 0.15 and the mean SWSEET was 11.28 ± 2.58 kPa. The results have proven that the stiffness of ETs is lower or equal to the thyroid's. SWE was demonstrated to be a useful diagnostic method for ET evaluation. Therefore, the application of SWE in ET diagnosis allows more accurate evaluation of ET-like lesions and, in many cases, allows one to avoid invasive procedures, simultaneously providing a precise monitoring method based on combined US and SWE evaluation.
More Related Videos
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
The Thyroid Gland
The follicles have a central cavity lined by simple cuboidal to squamous epithelial cells called follicular cells. These cells produce the glycoprotein...
Imaging Studies II: Ultrasonography
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):