Kazuhisa Kishi1, Noriyuki Kaji1,2, Yoshiharu Tsuru3
1Department of Veterinary Pharmacology, Graduate School of Agriculture and Life Sciences, The University of Tokyo, Tokyo, Japan.
Introduction:
Colonic motility disorders are a frequent clinical problem caused by various drugs and diseases. However, the etiology of colonic dysmotility is often unclear due to the lack of in vivo methods, including rapid dynamic assessment.
Objectives:
The aim of this study was to establish a novel quantitative method to objectively assess colonic motility using ultrasonography.
Methods:
We applied echocardiographic speckle tracking-based strain imaging to analyze murine colonic motility. A trace line was placed on the boundary between the proximal wall of the colon and the inner cavity to analyze colonic wall displacement and strain rate. Locomotion activities of the colonic wall were used to quantify colonic motility via ultrasonography.
Results:
We found that ultrasonography can quantitatively detect a decrease in colonic motility induced by loperamide, an antidiarrheal drug. These quantitative data were consistent with the imaging findings of colonic peristalsis and colon transit time. Additionally, ultrasonography also revealed changes in colonic motility over short intervals. Furthermore, we have shown that ultrasonography can quantitatively and noninvasively detect colonic dysmotility and hypervascularity of the colonic wall in colitis mice.
Conclusions:
These findings suggest that ultrasonography is a useful in vivo method for objectively monitoring changes in colonic motility caused by drugs and diseases.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called...