Efficient synergistic disinfection by ozone, ultraviolet irradiation and chlorine in secondary effluents
1Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Beijing Laboratory for Environmental Frontier Technologies, Beijing 100084, PR China.
Abstract:
Disinfection of secondary effluents is vital to provide a sustainable aquatic environment, minimize microbial risks and guarantee public and environmental safety. This study investigated the effectiveness of six treatment trains including single and combined disinfection processes (i.e., ozone alone, ultraviolet (UV) irradiation alone, chlorine alone, sequential ozone-UV, sequential ozone-chlorine and sequential ozone-UV-chlorine) on bacterial inactivation, as well as bulk water quality parameters such as color, turbidity, absorbance at 254 nm (UV254), dissolved organic carbon (DOC) and fluorescence based on samples collected from an actual water reclamation plant (WRP). For the single disinfection processes, when the ozone, UV and chlorine doses reached 5 mg/L, 15 mJ/cm2 and 4 mg/L, respectively, the log removal of Escherichia coli (E. coli) reached 5 log. A trailing phenomenon was observed with further increases in the disinfectant dosage. Under the combined treatment scenarios, ozone pretreatment resulted in substantial removal of color, turbidity, UV254, fluorescence excitation-emission matrix (FEEM) and chlorine consuming organics, thus enhancing the efficiency of subsequent UV irradiation or chlorine treatments. In the sequential ozone-UV-chlorine experiments, E. coli inactivation reached 7 log with ozone, UV and available chlorine of 3 mg/L, 5 or 10 mJ/cm2 and 2.5 mg/L, respectively. On the basis of the results from the actual WRP, the estimated operating cost per unit for the disinfection systems is 0.065 CNY/t, which is economical for long-term operation.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
06:35Implementation of a Hyperbolic Vortex Plasma Reactor for the Removal of Micropollutants in Water
Published on: July 25, 2025
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Combined Effects of Drugs: Synergism
Such synergistic combinations...
Coagulation