Background:
During medical emergencies, one of the main steps to improve patient outcomes is to achieve airway management. Orotracheal intubation is highly effective for advanced airway management, but it requires experienced health professionals. The use of a supraglottic airway device (SAD) is an acceptable alternative.
Aim:
To assess which of the four considered SADs takes the shortest time and the lowest number of attempts to be correctly placed. The secondary aim was to evaluate the influence of some characteristics of the study population on time taken and number of attempts required.
Methods:
A crossover trial was conducted at the Advanced Medical Simulation Center of the University of Perugia (Italy) between June and September 2017. Eighty-three nurses were enrolled in the study. Each participant was asked to place four different SADs in a manikin: Laryngeal Tube Suction-D (LTS-D), i-gel™, Ambu® Laryngeal Mask AuraGain™ and LMA® Protector™ Cuff Pilot™.
Results:
The median insertion time for the different devices was: 8.0 seconds (s) for LTS-D, 6.0 s for i-gel, 5.4 s for AuraGain, 5.8 s for LMA Protector (p<0.05); the median number of insertion attempts was: 2 for LTS-D, 1 for i-gel, AuraGain and LMA Protector (p<0.05). There was no significant relationship between insertion time and attempts required and the participants' working experience, training, or knowledge of the devices.
Conclusion:
With the exception of LTS-D, which had the worst performance, there was a high degree of homogeneity between the studied SADs in terms of time and attempts required to achieve correct placement.
More Related Videos
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...