Related Experiment Video
Updated: Nov 27, 2025

Transmission of Multiple Signals through an Optical Fiber Using Wavefront Shaping
Published on: March 20, 2017
Revisiting Degrees of Freedom of Full-Duplex Systems with Opportunistic Transmission: An Improved User Scaling Law
Haksoo Kim1, Juyeop Kim2, Sang Won Choi3
1Affiliated Institute of ETRI, Daejeon 305-390, Korea.
Abstract:
It was recently studied how to achieve the optimal degrees of freedom (DoF) in a multi-antenna full-duplex system with partial channel state information (CSI). In this paper, we revisit the DoF of a multiple-antenna full-duplex system using opportunistic transmission under the partial CSI, in which a full-duplex base station having M transmit antennas and M receive antennas supports a set of half-duplex mobile stations (MSs) having a single antenna each. Assuming no self-interference, we present a new hybrid opportunistic scheduling method that achieves the optimal sum DoF under an improved user scaling law. Unlike the state-of-the-art scheduling method, our method is designed in the sense that the scheduling role between downlink MSs and uplink MSs is well-balanced. It is shown that the optimal sum DoF of 2 M is asymptotically achievable provided that the number of MSs scales faster than SNR M , where SNR denotes the signal-to-noise ratio. This result reveals that, in our full-duplex system, better performance on the user scaling law can be obtained without extra CSI, compared to the prior work that showed the required user scaling condition (i.e., the minimum number of MSs for guaranteeing the optimal DoF) of SNR 2 M - 1 . Moreover, the average interference decaying rate is analyzed. Numerical evaluation is performed to not only validate our analysis but also show superiority of the proposed method over the state-of-the-art method.
Related Concept Videos
Transmission Line Design Considerations
Transmission-Line Differential Equations
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured from...
Maximum Power Transfer
By substituting the entire circuit with...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily...
Degrees of Freedom
For example, suppose there are three unknown numbers whose mean is 10; although we can freely assign values to the first and second numbers, the value of the last number can not be arbitrarily assigned.
Cascaded Op Amps
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...

