New Arc Stability Index for Industrial AC Three-Phase Electric Arc Furnaces Based on Acoustic Signals

Juan Guerra-Serrano1, Angel Sánchez-Roca2, Guillermo González-Yero3

  • 1Integral Automation Company (CEDAI), L.Ortiz No.36 Esq.Lora, Las Tunas 75100, Cuba.

Related Concept Videos

Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
517
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle01:19

Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle

Inductively coupled plasma (ICP) is the most widely used plasma source in atomic emission spectroscopy (AES), also known as Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES). The ICP source, or torch, consists of three concentric quartz tubes with argon gas flowing through them. A spark from a Tesla coil initiates the ionization of argon, generating a high-temperature plasma.
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
1.3K
Power in a Three-Phase Circuit01:15

Power in a Three-Phase Circuit

Three-phase systems have two configurations: the wye and delta. A star configuration can be three or four wires; in a delta configuration, the components are connected in a closed loop. Instantaneous power refers to the power value at a precise moment, and in a balanced three-phase system, it is constant. This is because the sum of the instantaneous powers in the three phases remains steady over time, despite individual fluctuations, due to the symmetry and phase relationship. The total...
505
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
607
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
407
RMS Value in AC Circuit01:13

RMS Value in AC Circuit

The root mean square (RMS) value is a measure of the effective or average value of an alternating current (AC) waveform. In AC circuits, the voltage or current waveform constantly changes direction and magnitude, making it difficult to describe with a single value. The RMS value provides a convenient way to calculate the equivalent DC voltage or current that would produce the same heating effect in a resistor as the AC waveform.
Mathematically, the RMS value of an AC waveform is the square root...
2.9K