An optimized SDS-PAGE protocol with a new blotting system for the initial testing procedure of ESAs in doping control
Laurent Martin1, Jean-Antoine Martin1, Michel Audran1
1Analysis Department, Agence Française de Lutte contre le Dopage (AFLD), Châtenay-Malabry, France.
Abstract:
Recombinant erythropoietins (rEPOs) are still among the substances endurance athletes use for doping. Detection methods are based on an electrophoretic separation of the proteins followed by a western blot and immunodetection with specific anti-EPO antibodies. In addition to IEF-PAGE, the SDS-PAGE method has been used to differentiate endogenous EPO from rEPOs by their molecular weight (MW). However, to adapt to new generations of rEPOs exhibiting higher MW, which were not well detected after SDS-PAGE, sodium lauroyl sarcosinate (SAR) is now used instead of sodium dodecyl sulfate (SDS) for the initial EPO testing procedure on doping control samples. The SAR-PAGE method is nevertheless expensive as it requires frequent buffer preparations using highly purified sarkosyl powder. In addition, this reagent needs to be handled with care due to acute toxicity by inhalation. The aim of this work was to improve the SDS-PAGE method by increasing its sensitivity and transfer of high-MW rEPOs. First, using a biotinylated primary anti-EPO antibody and avoiding the use of a secondary antibody increased the general sensitivity of both SDS-PAGE and SAR-PAGE to all rEPOs about four-fold. Then, by changing the buffer system during the protein transfer, with a CAPS buffer and a discontinuous buffer transfer system, high-MW rEPOs, EPO-Fc and CERA were transferred with higher efficiency and detected with high sensitivity. This optimized SDS-PAGE protocol could be adopted by anti-doping laboratories as an alternative to SAR-PAGE.
More Related Videos
09:58An Optimized Protocol for Electrophoretic Mobility Shift Assay Using Infrared Fluorescent Dye-labeled Oligonucleotides
Published on: November 29, 2016
10:21Author Spotlight: Streamlining Protein Target Prediction and Validation via Molecular Docking and CETSA
Published on: February 23, 2024
Related Concept Videos
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...