Background:
The likelihood of advanced or synchronous neoplasms is significantly higher in fecal immunochemical test (FIT)-positive individuals than in the general population. The magnitude of the colonoscopy-related complication rate in FIT-positive individuals remains unknown. This study aimed to elucidate the colonoscopy-related complication rate after a positive FIT result and compare it with the rate when colonoscopy was performed for other purposes.
Methods:
Information regarding colonoscopy-related severe complications after a positive FIT result (FIT-colonoscopy) and ordinary colonoscopy during 2010-2014 was collected from the Taiwanese Colorectal Cancer Screening Program Database and National Health Insurance Research Database. Severe complications included significant bleeding, perforation, and cardiopulmonary events ≤ 14 days after colonoscopy. The number of events per 1000 procedures was used to quantify complication rates. Multivariate analysis was conducted to assess the association of various factors with severe complications associated with FIT-colonoscopy compared with ordinary colonoscopy.
Results:
319 114 FIT-colonoscopies (214 955 patients) were identified, 51 242 (16.1 %) of which included biopsy and 94 172 (29.5 %) included polypectomy. Overall, 2125 significant bleedings (6.7 ‰) and 277 perforations (0.9 ‰) occurred ≤ 14 days after FIT-colonoscopy. Polypectomy, antiplatelet use, and anticoagulant use were associated with higher risk of complications (adjusted odds ratio [aOR] 4.41, 95 % confidence interval [CI] 4.05-4.81); aOR 1.35, 95 %CI 1.12-1.53; aOR 1.88, 95 %CI 0.61-5.84, respectively). Compared with ordinary colonoscopy, FIT-colonoscopy involved significantly higher risk of significant bleeding (aOR 3.10, 95 %CI 2.90-3.32).
Conclusions:
FIT-colonoscopy was associated with a more than two-fold risk of significant bleeding, especially when polypectomy was performed.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
06:46Competing-Risk Nomogram for Predicting Cancer-Specific Survival in Multiple Primary Colorectal Cancer Patients after Surgery
Published on: September 27, 2024
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Inflammatory Bowel Disease I: Ulcerative Colitis
Inflammatory bowel disease, or IBD, encompasses a group of disorders characterized by chronic inflammation or ulceration of the gastrointestinal tract.
Risk Factors
The exact cause of IBD remains unclear, although it is believed to be due to a mix of genetic, environmental, microbial, and immune factors. Genetic factors are significant in determining susceptibility to IBD, with family history being a critical risk factor. Individuals with a first-degree relative who has IBD are at...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...