Related Experiment Video
Updated: Nov 27, 2025

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Functional Outcome of Intraarticular Fracture of Distal Radius Managed by Volar Locking Plate
Masroor Ahmed1, Naveed Ahmed2, Sunil Kumar3
1Orthopedic Surgery, Shaheed Mohtarma Benazir Bhutto Medical College Lyari, Karachi, PAK.
Abstract:
Objective This study's main purpose is to determine the functional outcome of volar locking plates in the management of intraarticular fracture of the distal radius. Methodology This cross-sectional study was conducted from August 2016 to August 2019. Forty-nine patients with the intraarticular distal radius fractures managed by the volar locking plate were included in the study. Patients with open fractures, ipsilateral other limb injuries, polytrauma patients, pathological fractures, and patients having neurovascular injuries were excluded from the study. AO Classification was used to classify fractures. The fracture was approached through the volar approach and fixed by the volar locking plate. A modified mayo wrist score evaluated the functional outcome. All the data were recorded on predesigned performa, and Statistical Package for the Social Sciences (SPSS), version 20 (IBM Corp., Armonk, NY) was used to analyze the data. Results A total of 49 patients with intraarticular fractures of the distal radius were included in the study. The mean age of the patient was 37.20 ± 10.05 years. Out of 49 patients, 29 (59.2%) were males, and 20 (40.8%) were females. Union was achieved in almost all fractures except one case, which went into non-union despite the adequate initial reduction, and the mean time of union was 11.98 ± 1.64 weeks. With respect to the stratification of functional outcome very good and good functional outcome was achieved in 46 patients (93.8%) in both the groups, the satisfactory outcome was achieved in two (4.1%) cases and one patient had a bad outcome in which union was not achieved and went into non-union. Conclusion Open reduction and internal fixation of intraarticular fracture of the distal radius using a volar locking plate is a good option for managing these fractures as it provides stable fixation, and good to excellent outcomes can be achieved by using these plates.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Ulna

